Model: ZEC
| Rated capacity | D1 | D2 | H | H1 | H2 | H3 | W | W1 | L | L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 10t | 80 | 18 | 170 | 30 | 110 | 16 | 140 | 100 | 130 | 80 |
| 20t | 90 | 18 | 175 | 30 | 115 | 19 | 140 | 100 | 130 | 80 |
| 30t | 100 | 22 | 205 | 40 | 125 | 22 | 190 | 130 | 170 | 110 |
| 50t~70t | 125 | 22 | 255 | 50 | 155 | 45 | 200 | 140 | 180 | 120 |
| 100t~150t | 165 | 26 | 340 | 70 | 200 | 32 | 240 | 160 | 230 | 160 |
| 200t~300t~400t | 223 | 39 | 495 | 110 | 275 | 45 | 340 | 250 | 340 | 250 |
SPECIFICATION:
| Rated capacity: 10ton to 400ton | Operating temperature range: -30 to +70℃ |
|---|---|
| Rated output: 2.0±0.002mv/v | Maximum safe overload: 150% OF R.C |
| Combined error: ±0.03% F.S(10t~50t); ±0.05% F.s (70t~100t); ±0.1% F.S (150t~400t) | Ultimate safe overload: 200% OF R.C |
| Non-repeatability: ±0.03% F.S | Recommended Excitation: 10 to 12V DC |
| Non-linearity: ±0.03% F.S;±0.05% F.S | Maximum Excitation: 15V DC |
| Hysteresis error: ±0.03% F.S | Environment protection: IP68 |
| Zero balance: ±1% F.S | Input impedance: 400±20Ω |
| Creep error(30minutes): ±0.03% F.S | Output impedance: 352±3Ω |
| Temperature effect on zero: ±0.03% F.S | Insulation resistance at 50V DC: ≥5000MΩ |
| Temperature effect on output: ±0.03% F.S | Material: alloy steel(ZSC-A);Stainless Steel(ZSC-ASS) |
| Compensated temperature range: -10 to +40℃ | Cable: length_8meter(10t), 12meter(20t), 14meter(30t), 16meter(50t~150t), 20meter(200t~400t), Diameter - Φ6mm(10t);Φ8mm(20t~400t) |